ISO 5167-5:2022

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ١١ أكتوبر ٢٠٢٢

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 5: Cone meters

ملفات الوثيقة ISO 5167-5:2022

الإنجليزية 15 صفحات
الإصدار الحالي
118.28 USD

مجال الوثيقة ISO 5167-5:2022

This document specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit.

As the uncertainty of an uncalibrated cone meter might be too high for a particular application, it might be deemed essential to calibrate the flow meter in accordance with Clause 7.

This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1.

This document is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, β, and Reynolds number, Re. This document is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 × 104 or greater than 1,2 × 107.

A cone meter is a primary device which consists of a cone-shaped restriction held concentrically in the centre of the pipe with the nose of the cone upstream. The design of cone meter defined in this document has one or more upstream pressure tappings in the wall, and a downstream pressure tapping positioned in the back face of the cone with the connection to a differential pressure transmitter being a hole through the cone to the support bar, and then up through the support bar.

Alternative designs of cone meters are available; however, at the time of writing, there is insufficient data to fully characterize these devices, and therefore, these meters shall be calibrated in accordance with Clause 7.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
YSMO GSO 150-2:2020
GSO 150-2:2013 
لائحة فنية يمنية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
YSMO GSO 2055-1:2020
GSO 2055-1:2015 
مواصفة قياسية يمنية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال
GSO 2055-1:2015
 
لائحة فنية خليجية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال

اعتمدت مؤخراً

ISO 15964:2025
 
مواصفة قياسية دولية
Detection and avoidance systems for uncrewed aircraft systems
ISO 5175-3:2025
 
مواصفة قياسية دولية
Gas welding equipment — Safety devices — Part 3: Decomposition blockers for low-pressure acetylene
ISO 29461-4:2025
 
مواصفة قياسية دولية
Air intake filter systems for rotary machinery — Part 4: Test methods for static filter systems in coastal and offshore environments
ISO 3451-5:2025
 
مواصفة قياسية دولية
Plastics — Determination of ash — Part 5: Poly(vinyl chloride)